Control unit package for cell culture, photo version, HABITAT photo cell

item number: 1430032
manufacturer number:  
0010007553

PU: Unit

Currently we do not have a price for this item in the system. However, you can request the product from customer service with just one click.

on the way: ships in 3 to 5 days
on the way: ships in 3 to 5 days
favorite

Control unit package for cell culture, photo version, HABITAT photo cell

PU: Unit

The HABITAT photo cell control unit package of the HABITAT research bioreactor is used to monitor and control the bioprocess. With the help of the LED panels included in the scope of delivery, the system can be used as a photobioreactor, for example for algae cultivation. The adjustment of the light intensity enables the simulation of the day-night rhythm. Furthermore,, the package includes the control unit with all connection options for the gas supply, liquid addition, sensors and temperature control as well as a tablet for simple and clear operation of the bioreactor.

Control and monitoring
The bioprocess and all associated test parameters can be easily controlled and monitored via the tablet attached to the control unit and with the help of the intuitive and easy-to-use software. Depending on the type of cultivation, you can choose between the operating modes batch, fed-batch and perfusion/continuous. The new Chaotic Mixing function ensures faster and more effective mixing when required. The 10.4-inch tablet allows direct access to all actuators directly on the main screen. A clear calibration management, a diagram overview and the complete documentation of the process round off the operation. A software version that meets FDA CFR Part 11 requirements is available as an option.

Gas supply
Built in mass flow controllers for 4 separate gas lines (for N2, O2, air and CO2) ensure precise, individually adjustable gassing, ideally tailored to the needs of your cells. Flow rates of 0-2000 cc/min can be achieved.

Liquid supply
4 integrated Watson Marlow pumps, adjustable in direction and speed, give you the variability to pump in and pump out different liquids (like acid, base, anti-foam agent, feeding solutions).

Sensors
HABITAT photo cell enables the measurement of the following parameters by means of sensors:
• pH
• DO (dissolved oxygen)
• temperature
• filling level
• foam

Temperature control
The constant and precise temperature control during the cultivation is guaranteed by the heating sleeve, which is adapted to the respective vessel size. (Heating sleeve is included with the HABITAT cell vessel package).

All features at a glance
- compact, space-saving design, dimensions: 223 x 402 x 450 mm (WxDxH)
- large tablet for clear operation (10,4 inch)
- intuitive, easy-to-use software with a lot of functionalities.
- 4 integrated fast-load pumps (Watson Marlow)
- connectivity: USB, PC, RS232, ethernet, external signal input, external pump, single-use unit, thermostat
- data storage
- gas supply with 4 built-in mass flow controllers: e.g. for O2, Luft, N2, CO2
- Status LED display: direct error display by indicator light

Note: Only a control tower package and the separately available vessel package make up a functional unit.

Controller: Cell Growth
Operating mode: timer, continuous and program operation
Display: Tablet PC
Operation: touch screen
Data memory size [GB]: 32
Auto restart after power failure: yes
Ethernet interface: yes
Single use reactor interface: yes
Thermostat interface: yes
Ext. pump interface: yes
Filter heater: yes
LED light panel: yes
Stirring motor: yes
Calibration guide tepmerature: yes
Calibration guide pH: yes
Calibration guide pO2: yes
pH - temperature compensation: yes
Mode hose filling: yes
Stirrer control mode: off, manual, profile, Cascade-pO2 control, chaotic
Speed range [rpm]: 1 - 2200
Speed deviation >= 100 rpm [%]: ±2
Speed deviation <= 100 rpm [rpm]: ±5
Speed display: TFT
Reversible direction of rotation : yes
Timer: yes
Timer display: TFT
Time setting range [min]: 1 - 120
Heating blanket: yes
Heat output [W]: 250
Heat control: TFT
Temperature control: PT1000
Working temperature [°C]: 5 - 60
Connection for ext. temperature sensor: PT1000
Temperature display: yes
Temperature measuring range [°C]: 0 - 100
Temperature measurement resolution [K]: 0.1
Temperature control accuracy [°C]: ±0.2
Temperature limit min. [°C]: 0
Temperature limit max. [°C]: 110
Fixed safety circuit [°C]: 75
pH measurement: yes
pH control mode: off, auto, profile
pH value display: TFT
pH measuring range [pH]: 0 - 14
pH measurement resolution [pH]: 0.01
Accuracy of pH measurement [pH]: 0.02
Conncetion for pO2 sensor: yes
pO2 control mode: off, manual, auto, profile
Measurement range pO2 min. [%sat]: 0
Measurement range pO2 max. [%sat]: 200
Resolution pO2 measurement [%sat]: 0.01
Accuracy of pO2 measurement [%sat]: 0.3
Conncetion for turbidity sensor: no
Conncetion for conductivity sensor: no
Conncetion for CO2 sensor: no
Gas in connection Air [mm]: 6
Gas out connection Air [mm]: 6
Gas in connection O2 [mm]: 6
Gas out connection O2 [mm]: 6
Gas in connection N2 [mm]: 6
Gas out connection N2 [mm]: 6
Gas in connection CO2 [mm]: 6
Gas out connection CO2 [mm]: 6
Aeration mode: continuous & automatic
Display flowrate: l/min, cc/min
Input pressure [mbar]: 200 - 3000
Pressure out min. [mbar]: 200
Pressure out max. [mbar]: 1000
Flowrate Air min. [cc/min]: 0
Flowrate Air max. [cc/min]: 2000
Flowrate O2 min. [cc/min]: 0
Flowrate O2 max. [cc/min]: 2000
Flowrate N2 min. [cc/min]: 0
Flowrate N2 max. [cc/min]: 2000
Flowrate CO2 min. [cc/min]: 0
Flowrate CO2 min. [cc/min]: 2000
Measuring and control accuracy of the gas control units [% fsr]: 2
Peristaltic pump: yes
Numbers of pump heads: 4
Pump head function: Acid, Base, AntiFoam, Level
Pump head: Watson Marlowe 114DV
Number of pump tubes: 4
Number of pump rollers: 4
Flow rate min. [ml/min]: 0.3
Flow rate max. [ml/min]: 270
Pump Speed min. [rpm]: 30
Pump Speed max. [rpm]: 400
Pump reversible direction of rotation: yes
Pump speed display: TFT
Inner tube diameter min. [mm]: 0.5
Inner tube diameter max. [mm]: 4.8
Tube outer diamter min. [mm]: 4.1
Tube outer diamter max. [mm]: 8.4
Tube material : Silicone
Tube hardness [Shore A]: 50 - 60
Dimensions (W x H x D) [mm]: 224 x 624 x 405
Weight [kg]: 14
Permissible ambient temperature [°C]: 5 - 40
Permissible ambient conditions: 80% (up to 31°C), decreasing linearly to max. 50 (@40°C)
Protection class according to DIN EN 60529: IP 20
RS 232 interface: yes
USB interface: yes
WiFi Interface: yes
Voltage [V]: 100 - 240
Frequency [Hz]: 50/60
Power input [W]: 300
Power input max. [W]: 1100
Power input standby [W]: 10
Fuse: 1x T6.3A 250V

Mit dem Laden des Videos akzeptieren Sie die Datenschutzerklärung von YouTube.

Product Description

Control unit package for cell culture, photo version, HABITAT photo cell

PU: Unit

The HABITAT photo cell control unit package of the HABITAT research bioreactor is used to monitor and control the bioprocess. With the help of the LED panels included in the scope of delivery, the system can be used as a photobioreactor, for example for algae cultivation. The adjustment of the light intensity enables the simulation of the day-night rhythm. Furthermore,, the package includes the control unit with all connection options for the gas supply, liquid addition, sensors and temperature control as well as a tablet for simple and clear operation of the bioreactor.

Control and monitoring
The bioprocess and all associated test parameters can be easily controlled and monitored via the tablet attached to the control unit and with the help of the intuitive and easy-to-use software. Depending on the type of cultivation, you can choose between the operating modes batch, fed-batch and perfusion/continuous. The new Chaotic Mixing function ensures faster and more effective mixing when required. The 10.4-inch tablet allows direct access to all actuators directly on the main screen. A clear calibration management, a diagram overview and the complete documentation of the process round off the operation. A software version that meets FDA CFR Part 11 requirements is available as an option.

Gas supply
Built in mass flow controllers for 4 separate gas lines (for N2, O2, air and CO2) ensure precise, individually adjustable gassing, ideally tailored to the needs of your cells. Flow rates of 0-2000 cc/min can be achieved.

Liquid supply
4 integrated Watson Marlow pumps, adjustable in direction and speed, give you the variability to pump in and pump out different liquids (like acid, base, anti-foam agent, feeding solutions).

Sensors
HABITAT photo cell enables the measurement of the following parameters by means of sensors:
• pH
• DO (dissolved oxygen)
• temperature
• filling level
• foam

Temperature control
The constant and precise temperature control during the cultivation is guaranteed by the heating sleeve, which is adapted to the respective vessel size. (Heating sleeve is included with the HABITAT cell vessel package).

All features at a glance
- compact, space-saving design, dimensions: 223 x 402 x 450 mm (WxDxH)
- large tablet for clear operation (10,4 inch)
- intuitive, easy-to-use software with a lot of functionalities.
- 4 integrated fast-load pumps (Watson Marlow)
- connectivity: USB, PC, RS232, ethernet, external signal input, external pump, single-use unit, thermostat
- data storage
- gas supply with 4 built-in mass flow controllers: e.g. for O2, Luft, N2, CO2
- Status LED display: direct error display by indicator light

Note: Only a control tower package and the separately available vessel package make up a functional unit.

Technical Data

Controller: Cell Growth
Operating mode: timer, continuous and program operation
Display: Tablet PC
Operation: touch screen
Data memory size [GB]: 32
Auto restart after power failure: yes
Ethernet interface: yes
Single use reactor interface: yes
Thermostat interface: yes
Ext. pump interface: yes
Filter heater: yes
LED light panel: yes
Stirring motor: yes
Calibration guide tepmerature: yes
Calibration guide pH: yes
Calibration guide pO2: yes
pH - temperature compensation: yes
Mode hose filling: yes
Stirrer control mode: off, manual, profile, Cascade-pO2 control, chaotic
Speed range [rpm]: 1 - 2200
Speed deviation >= 100 rpm [%]: ±2
Speed deviation <= 100 rpm [rpm]: ±5
Speed display: TFT
Reversible direction of rotation : yes
Timer: yes
Timer display: TFT
Time setting range [min]: 1 - 120
Heating blanket: yes
Heat output [W]: 250
Heat control: TFT
Temperature control: PT1000
Working temperature [°C]: 5 - 60
Connection for ext. temperature sensor: PT1000
Temperature display: yes
Temperature measuring range [°C]: 0 - 100
Temperature measurement resolution [K]: 0.1
Temperature control accuracy [°C]: ±0.2
Temperature limit min. [°C]: 0
Temperature limit max. [°C]: 110
Fixed safety circuit [°C]: 75
pH measurement: yes
pH control mode: off, auto, profile
pH value display: TFT
pH measuring range [pH]: 0 - 14
pH measurement resolution [pH]: 0.01
Accuracy of pH measurement [pH]: 0.02
Conncetion for pO2 sensor: yes
pO2 control mode: off, manual, auto, profile
Measurement range pO2 min. [%sat]: 0
Measurement range pO2 max. [%sat]: 200
Resolution pO2 measurement [%sat]: 0.01
Accuracy of pO2 measurement [%sat]: 0.3
Conncetion for turbidity sensor: no
Conncetion for conductivity sensor: no
Conncetion for CO2 sensor: no
Gas in connection Air [mm]: 6
Gas out connection Air [mm]: 6
Gas in connection O2 [mm]: 6
Gas out connection O2 [mm]: 6
Gas in connection N2 [mm]: 6
Gas out connection N2 [mm]: 6
Gas in connection CO2 [mm]: 6
Gas out connection CO2 [mm]: 6
Aeration mode: continuous & automatic
Display flowrate: l/min, cc/min
Input pressure [mbar]: 200 - 3000
Pressure out min. [mbar]: 200
Pressure out max. [mbar]: 1000
Flowrate Air min. [cc/min]: 0
Flowrate Air max. [cc/min]: 2000
Flowrate O2 min. [cc/min]: 0
Flowrate O2 max. [cc/min]: 2000
Flowrate N2 min. [cc/min]: 0
Flowrate N2 max. [cc/min]: 2000
Flowrate CO2 min. [cc/min]: 0
Flowrate CO2 min. [cc/min]: 2000
Measuring and control accuracy of the gas control units [% fsr]: 2
Peristaltic pump: yes
Numbers of pump heads: 4
Pump head function: Acid, Base, AntiFoam, Level
Pump head: Watson Marlowe 114DV
Number of pump tubes: 4
Number of pump rollers: 4
Flow rate min. [ml/min]: 0.3
Flow rate max. [ml/min]: 270
Pump Speed min. [rpm]: 30
Pump Speed max. [rpm]: 400
Pump reversible direction of rotation: yes
Pump speed display: TFT
Inner tube diameter min. [mm]: 0.5
Inner tube diameter max. [mm]: 4.8
Tube outer diamter min. [mm]: 4.1
Tube outer diamter max. [mm]: 8.4
Tube material : Silicone
Tube hardness [Shore A]: 50 - 60
Dimensions (W x H x D) [mm]: 224 x 624 x 405
Weight [kg]: 14
Permissible ambient temperature [°C]: 5 - 40
Permissible ambient conditions: 80% (up to 31°C), decreasing linearly to max. 50 (@40°C)
Protection class according to DIN EN 60529: IP 20
RS 232 interface: yes
USB interface: yes
WiFi Interface: yes
Voltage [V]: 100 - 240
Frequency [Hz]: 50/60
Power input [W]: 300
Power input max. [W]: 1100
Power input standby [W]: 10
Fuse: 1x T6.3A 250V