Horizontal double-door autoclave Systec HX-650 2D
item number: | 1295804 |
item number old: | 5437370 |
manufacturer number: |
2265
|
PU: Unit
Currently we do not have a price for this item in the system. However, you can request the product from customer service with just one click.
images similar
This item will be shipped to Germany only. For shipments to other countries, please use our Contact Form.
Horizontal double-door autoclave Systec HX-650 2D
PU: Unit
Standard features:
- Integrated, separate steam generator.
- Housing, support frame and pressure vessel made of corrosion-resistant st. steel.
- Temperature and pressure range 140 °C, 4 bar.
- Touch-screen control.
- Number of sterilisation programmes: up to 100.
- Code-secured access rights for changing parameters and further safety-relevant intervention.
- Internal memory for storing up to 500 sterilisation cycles.
- Timer for starting programmes.
- Flexible PT-100 temperature sensor.
- Additional temperature sensor in condense exhaust.
- Temperature holding function for liquids after programme finish.
- Special programme for Durham tubes.
- Calculation of F0 value.
- Special programme for waste sterilisation with pulsed heat-up for more efficient air exhaust.
- Water-cooled steam exhaust, thermostatically controlled.
- Programmable automatic door-opening on completion of programme.
- RS-232 and RS-485 interfaces for external data transmission (network-compatible).
Triple safety aspects:
- Only one door can be opened at a time. If one door is open, the other is automatically locked.
- If the autoclave is switched off or if no current is available (e. g. power failure), both doors remain locked.
- If the door at the non-sterile side is opened, a sterilisation programme has to be performed before the door at the sterile side can be opened.
The locking system can be adapted to customers' wishes. Doors and control panel are made of heat-insulating plastic, the housing completely of st. steel and the st. steel edges specially processed for smooth junctions with walls. Operation, however, can be carried out from both sides, the position (open or closed) of the opposite door being indicated on the display.
For use under the most stringent clean room and safety conditions:
- For biological safety laboratories: fitting as a sterilisation and pass-through lock for protecting the external environment.
- For clean rooms in laboratories and production facilities: as a sterilisation and pass-through lock separating sterile and non-sterile areas.
Chamber volume [l]: | 700 l |
Chamber volume, nominal [l]: | 650 l |
Chamber inner diameter [mm]: | 740 mm |
Chamber depth [mm]: | 1.500 mm |
Width [mm]: | 930 mm |
Mains supply: | no indication |
Depth [mm]: | 1.960 mm |
Height [mm]: | 1.683 mm |
Type: | Systec HX-650 2D |
Description: | keine Angabe |
Current [A]: | 32 A |
Product Description
Horizontaler Durchreiche-Autoklaven Systec HX-650 2D
PU: Unit
Standard features:
- Integrated, separate steam generator.
- Housing, support frame and pressure vessel made of corrosion-resistant st. steel.
- Temperature and pressure range 140 °C, 4 bar.
- Touch-screen control.
- Number of sterilisation programmes: up to 100.
- Code-secured access rights for changing parameters and further safety-relevant intervention.
- Internal memory for storing up to 500 sterilisation cycles.
- Timer for starting programmes.
- Flexible PT-100 temperature sensor.
- Additional temperature sensor in condense exhaust.
- Temperature holding function for liquids after programme finish.
- Special programme for Durham tubes.
- Calculation of F0 value.
- Special programme for waste sterilisation with pulsed heat-up for more efficient air exhaust.
- Water-cooled steam exhaust, thermostatically controlled.
- Programmable automatic door-opening on completion of programme.
- RS-232 and RS-485 interfaces for external data transmission (network-compatible).
Triple safety aspects:
- Only one door can be opened at a time. If one door is open, the other is automatically locked.
- If the autoclave is switched off or if no current is available (e. g. power failure), both doors remain locked.
- If the door at the non-sterile side is opened, a sterilisation programme has to be performed before the door at the sterile side can be opened.
The locking system can be adapted to customers' wishes. Doors and control panel are made of heat-insulating plastic, the housing completely of st. steel and the st. steel edges specially processed for smooth junctions with walls. Operation, however, can be carried out from both sides, the position (open or closed) of the opposite door being indicated on the display.
For use under the most stringent clean room and safety conditions:
- For biological safety laboratories: fitting as a sterilisation and pass-through lock for protecting the external environment.
- For clean rooms in laboratories and production facilities: as a sterilisation and pass-through lock separating sterile and non-sterile areas.
Technical Data
Chamber volume [l]: | 700 l |
Chamber volume, nominal [l]: | 650 l |
Chamber inner diameter [mm]: | 740 mm |
Chamber depth [mm]: | 1.500 mm |
Width [mm]: | 930 mm |
Mains supply: | no indication |
Depth [mm]: | 1.960 mm |
Height [mm]: | 1.683 mm |
Type: | Systec HX-650 2D |
Description: | keine Angabe |
Current [A]: | 32 A |