Dry block heater, 4 blocks, Dry Block Heater 4
item number: | 1180466 |
item number old: | 5430581 |
manufacturer number: |
4025400
|
PU: Unit
plus shipping & VAT if applicable
Dry block heater, 4 blocks, Dry Block Heater 4
PU: Unit
Digital block heaters for 1, 2, 3 or 4 aluminium blocks provide precise temperature control in small vessels. Incl. PT 1000 temperature sensor, allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations and in situ hybridisations.
- Stepless adjustable temperature up to 120 °C.
- Timer: countdown, adjustable from 1 s to 99 h 59 min.
- Counter: display of heating time.
- Highly versatile with a large number of blocks.
- Error code display.
- Fixed safety circuit.
- Acoustic signal at end of test.
- Incl. PT 1000.60.
Max. heating temperature [°C]: | 120 °C |
Cooling: | no indication |
Width [mm]: | 151 mm |
Timer function: | yes |
Depth [mm]: | 465 mm |
Height [mm]: | 73 mm |
No. of exchange blocks: | 4 |
Heating power [W]: | 412 W |
Type: | DRY BLOCK HEATER 4 |
Description: | Aufstellfläche 96 x 304 mm |
Heating temperature range: | RT + 5 to 120 °C |
Heat control: | LED |
Connection for external temperature sensor: | DIN 12 878 |
Control accuracy with sensor: | ± 1 K |
Temperature constancy in medium: | ± 1 K |
Timer: | yes |
Protection class acc. to DIN EN 60529: | IP 21 |
Mains supply: | 220 to 240 V, 50 / 60 Hz |
Product Description
Dry block heater, 4 blocks, Dry Block Heater 4
PU: Unit1 Unit
Digital block heaters for 1, 2, 3 or 4 aluminium blocks provide precise temperature control in small vessels. Incl. PT 1000 temperature sensor, allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations and in situ hybridisations.
- Stepless adjustable temperature up to 120 °C.
- Timer: countdown, adjustable from 1 s to 99 h 59 min.
- Counter: display of heating time.
- Highly versatile with a large number of blocks.
- Error code display.
- Fixed safety circuit.
- Acoustic signal at end of test.
- Incl. PT 1000.60.
Technical Data
Max. heating temperature [°C]: | 120 °C |
Cooling: | no indication |
Width [mm]: | 151 mm |
Timer function: | yes |
Depth [mm]: | 465 mm |
Height [mm]: | 73 mm |
No. of exchange blocks: | 4 |
Heating power [W]: | 412 W |
Type: | DRY BLOCK HEATER 4 |
Description: | Aufstellfläche 96 x 304 mm |
Heating temperature range: | RT + 5 to 120 °C |
Heat control: | LED |
Connection for external temperature sensor: | DIN 12 878 |
Control accuracy with sensor: | ± 1 K |
Temperature constancy in medium: | ± 1 K |
Timer: | yes |
Protection class acc. to DIN EN 60529: | IP 21 |
Mains supply: | 220 to 240 V, 50 / 60 Hz |
Downloads
4 product variants
Item Title | Availability | Item #. | PU | List Price | Price | |
---|---|---|---|---|---|---|
Dry block heater, 1 block, Dry Block Heater 1 | 1180464 |
Unit | 1.116,25 € | |||
Dry block heater, 2 blocks, Dry Block Heater 2 | 1180465 |
Unit | 1.363,25 € | |||
Dry block heater, 3 blocks, Dry Block Heater 3 | 1180167 |
Unit | 1.597,90 € | |||
Dry block heater, 4 blocks, Dry Block Heater 4 | 1180466 |
Unit | 1.843,00 € |