Platform shaker Titramax 101

item number: 1179796
item number old: 5839832
manufacturer number:  
544-11300-00

PU: Unit

971,97 € 1.074,00 €

plus shipping & VAT if applicable

will be ordered: ships in 11 to 15 days
will be ordered: ships in 11 to 15 days
favorite

images similar

Platform shaker Titramax 101

PU: Unit

Temperature-controlled shaking.

Leading safety standards
- An overtemperature sensor preventively shuts off the unit in a dangerous heat-up situation - particularly valuable in case of continuous operation.
- For applications in microbiology: the insulated drive system prevents any heat build-up from the motor and consequently thermal damage to the sample.
- Immediate access: optional incubator hood opens instantly and interlocks in any position.

Superior ease of use
- Rule out accidents: all models have been designed with a low center of gravity which prevents gliding at high speed, even on a damp surface.
- Choose between different shaking motions, orbits, angles and load capacities: the right model for your specific application.
- Unlimited visual reaction control at all times: the transparent, non-fogging PETG material offers it all.

Reduced cost of ownership
- Increase your sample throughput and reduce your process times with the modular system for shaking, mixing and heating - all in one.
- Maintenance-free motors reduce repair and down times significantly to ensure years of continuous operation.

- The average operational lifespan of 10 years is backed by a 3 year warranty.

Vibrating.
For applications which require ridged or gentle shaking for small samples on microtiter plates or test tubes.

Titramax 100 - the compact model:
- With insulated system to prevent any heat transfer from the motor that could cause potential thermal damage to your sample.
- 1.5 mm vibration orbit.
- Speed can be set and continuously adjusted on the analog control knob from 150 to 1350 min-1.
- Analog process timer allows for unattended operation and can be set from 1 to 120 min. When the set time has elapsed an acoustic alarm will sound and operation stops.
- Space-saving unit, for load capacities of 2 kg, space for 4 microtiter plates.

Titramax 101 - the strong model:
- Like Titramax 100.
- Addionally: 3 mm vibration orbit.

Titramax 1000 - basic unit:
- With insulated system to prevent any heat transfer from the motor that could cause potential thermal damage to your sample.
- 1.5 mm vibration orbit.
- Speed can be set and continuously adjusted on the analog control knob from 150 to 1350 min-1.
- Analog process timer allows for unattended operation and can be set from 1 to 120 min. When the set time has elapsed an acoustic alarm will sound and operation stops.
- Addionally: increased throughput due to 6 microtiter plates.
- Medium-sized model, load capacities of 5 kg.
- Suitable for the modular incubator system, recommended for applications which require variable temperature control of up to 65 °C.

Items supplied with Titramax 1000 package:
- 1 x platform shaker Titramax 1000.
- 1 x heating module Incubator 1000.
- 1 x flat incubation hood.

Vibramax 100 - the compact model:
- Space-saving unit, for load capacities of 2 kg.
- 3 mm vibration orbit.
- Speed can be set and continuously adjusted on the analog control knob from 150 to 1350 min-1.
- A large selection of attachments is provided for the use of various vessels and sizes.
- Analog process timer allows for unattended operation and can be set from 1 to 120 min. When the set time has elapsed an acoustic alarm will sound and operation stops.
- Optional: attachment with tension rollers, attachments.

Vibramax 110 - the efficient model:
- With insulated system to prevent any heat transfer from the motor that could cause potential thermal damage to your sample.
- 1.5 mm vibration orbit.
- Speed can be set and continuously adjusted on the analog control knob from 150 to 1350 min-1.
- Analog process timer allows for unattended operation and can be set from 1 to 120 min. When the set time has elapsed an acoustic alarm will sound and operation stops.
- Ideal for the optional attachment to use 49 test tubes that increases throughput.

Max. speed [rpm]: 1.350 rpm
Max. load capacity [kg]: 2 kg
Shaking motion: no indication
Timer to [min]: 0
Colour: keine Angabe
Timer from [min]: 0
Shaking orbit [mm]: 3 mm
Weight [kg]: 5,5 kg
Type: Titramax 101
For: keine Angabe
Display: no indication
Description: keine Angabe

Product Description

Microtiter plate shakers,TITRAMAX 101

PU: Unit

Temperature-controlled shaking.

Leading safety standards
- An overtemperature sensor preventively shuts off the unit in a dangerous heat-up situation - particularly valuable in case of continuous operation.
- For applications in microbiology: the insulated drive system prevents any heat build-up from the motor and consequently thermal damage to the sample.
- Immediate access: optional incubator hood opens instantly and interlocks in any position.

Superior ease of use
- Rule out accidents: all models have been designed with a low center of gravity which prevents gliding at high speed, even on a damp surface.
- Choose between different shaking motions, orbits, angles and load capacities: the right model for your specific application.
- Unlimited visual reaction control at all times: the transparent, non-fogging PETG material offers it all.

Reduced cost of ownership
- Increase your sample throughput and reduce your process times with the modular system for shaking, mixing and heating - all in one.
- Maintenance-free motors reduce repair and down times significantly to ensure years of continuous operation.

- The average operational lifespan of 10 years is backed by a 3 year warranty.

Vibrating.
For applications which require ridged or gentle shaking for small samples on microtiter plates or test tubes.

Titramax 100 - the compact model:
- With insulated system to prevent any heat transfer from the motor that could cause potential thermal damage to your sample.
- 1.5 mm vibration orbit.
- Speed can be set and continuously adjusted on the analog control knob from 150 to 1350 min-1.
- Analog process timer allows for unattended operation and can be set from 1 to 120 min. When the set time has elapsed an acoustic alarm will sound and operation stops.
- Space-saving unit, for load capacities of 2 kg, space for 4 microtiter plates.

Titramax 101 - the strong model:
- Like Titramax 100.
- Addionally: 3 mm vibration orbit.

Titramax 1000 - basic unit:
- With insulated system to prevent any heat transfer from the motor that could cause potential thermal damage to your sample.
- 1.5 mm vibration orbit.
- Speed can be set and continuously adjusted on the analog control knob from 150 to 1350 min-1.
- Analog process timer allows for unattended operation and can be set from 1 to 120 min. When the set time has elapsed an acoustic alarm will sound and operation stops.
- Addionally: increased throughput due to 6 microtiter plates.
- Medium-sized model, load capacities of 5 kg.
- Suitable for the modular incubator system, recommended for applications which require variable temperature control of up to 65 °C.

Items supplied with Titramax 1000 package:
- 1 x platform shaker Titramax 1000.
- 1 x heating module Incubator 1000.
- 1 x flat incubation hood.

Vibramax 100 - the compact model:
- Space-saving unit, for load capacities of 2 kg.
- 3 mm vibration orbit.
- Speed can be set and continuously adjusted on the analog control knob from 150 to 1350 min-1.
- A large selection of attachments is provided for the use of various vessels and sizes.
- Analog process timer allows for unattended operation and can be set from 1 to 120 min. When the set time has elapsed an acoustic alarm will sound and operation stops.
- Optional: attachment with tension rollers, attachments.

Vibramax 110 - the efficient model:
- With insulated system to prevent any heat transfer from the motor that could cause potential thermal damage to your sample.
- 1.5 mm vibration orbit.
- Speed can be set and continuously adjusted on the analog control knob from 150 to 1350 min-1.
- Analog process timer allows for unattended operation and can be set from 1 to 120 min. When the set time has elapsed an acoustic alarm will sound and operation stops.
- Ideal for the optional attachment to use 49 test tubes that increases throughput.

Technical Data

Max. speed [rpm]: 1.350 rpm
Max. load capacity [kg]: 2 kg
Shaking motion: no indication
Timer to [min]: 0
Colour: keine Angabe
Timer from [min]: 0
Shaking orbit [mm]: 3 mm
Weight [kg]: 5,5 kg
Type: Titramax 101
For: keine Angabe
Display: no indication
Description: keine Angabe

Downloads

Manual

5 product variants

Item Title Availability Item #.PU List Price Price
Platform shaker Titramax 1010
will be ordered: ships in 11 to 15 days
1179795 Unit
1.073,00 € 971,06 €
Platform shaker Titramax 101
will be ordered: ships in 11 to 15 days
1179796 Unit
1.074,00 € 971,97 €
Platform shaker Vibramax 100
will be ordered: ships in 11 to 15 days
1179797 Unit
1.106,00 € 1.000,93 €
Platform shaker Titramax 1000
will be ordered: ships in 6 to 10 days
1179808 Unit
1.288,00 € 1.165,64 €
Titramax 1000 package, incl. platform shaker Titramax 1000, heating module Incubator 1000 and flat incubator hood
will be ordered: ships in 6 to 10 days
1179814 Unit
3.175,00 € 2.873,37 €

5 product variants

will be ordered: ships in 11 to 15 days
Item #: 1179795
PU: Unit
List Price: 1.073,00 €
Price: 971,06 €
will be ordered: ships in 11 to 15 days
Item #: 1179796
PU: Unit
List Price: 1.074,00 €
Price: 971,97 €
will be ordered: ships in 11 to 15 days
Item #: 1179797
PU: Unit
List Price: 1.106,00 €
Price: 1.000,93 €
will be ordered: ships in 6 to 10 days
Item #: 1179808
PU: Unit
List Price: 1.288,00 €
Price: 1.165,64 €
will be ordered: ships in 6 to 10 days
Item #: 1179814
PU: Unit
List Price: 3.175,00 €
Price: 2.873,37 €